Attic Ventilation Repair – Palo Alto, CA

Project Details

  • Location: South Ct., Palo Alto, CA 94301
  • Property Type: Residential
  • Project Dates: Completed in a single day on site (10 hours on site, two roofers, 20 combined labor hours)
  • Products Used: O’Hagin eave vents, plywood, fasteners
O’Hagin intake vents installed along the shingle roof to provide low-side airflow for balanced attic ventilation in Palo Alto, CA.

Project Summary

The Challenge

The rooms below this Palo Alto attic stayed uncomfortably warm no matter what the homeowner tried. That discomfort turned out to be a symptom, not the problem itself.

The attic already had a ridge vent, installed by a previous contractor, sitting at the roof’s peak to let hot air escape. Three gable-end vents were drawing air in and out through the vertical wall sections at each end of the attic, rather than letting it rise from the eaves and out the ridge. The eaves added a second complication: this home was built without an overhang–the space between the rafters that most rafter-vent systems depend on for their intake openings. With no overhang to work with, a standard rafter vent installation wasn’t possible.

Eastman applies the same intake-and-exhaust balance behind every attic ventilation retrofit it designs, and this attic had none: a working exhaust point with no functioning intake to match it.

Materials Used

Fasteners, plywood, and new O’Hagin vents. Plywood was installed over the gable end vents from inside the attic,  and the fasteners secured each vent to that deck.

O’Hagin intake vent installed on a shingle roof to improve attic ventilation in Palo Alto, CA.

Process

  • Evaluate the existing ridge vent and confirm how the gable vents and missing eave intake were working against it.
  • Seal the three gable-end vents to eliminate the competing airflow path with plywood.
  • Install and fasten the O’Hagin vents around the full eave line.
  • Check the finished attic for one coordinated path from intake to exhaust.

Highlights

No unexpected issues came up once work began, and the crew completed the project within a single 10-hour day on site. The O’Hagin system solved an intake problem standard eave vents couldn’t touch, given this home’s lack of overhang, and reusing the existing ridge vent kept the scope tied to the actual source of the problem instead of a full teardown. O’Hagin vents have screens to keep birds and rodents from using new roof openings as entry points.

Project Gallery

Key Specifications

DetailInformation
LocationPalo Alto, CA 94301
Property TypeResidential
Project Cost$6,415
Completion Time10 hours on site (2 roofers, 20 total labor hours)
Gable Vents Sealed3
O’Hagin Vents Installed12
Existing Ridge VentRetained and integrated
Unexpected IssuesNone

Special Features:

  • O’Hagin eave vent system, installed as a low-profile intake solution for a roof built without overhang.
  • An existing ridge vent was integrated into the corrected system rather than replaced.
  • A single visit that diagnosed and corrected three separate points of ventilation failure.
  • Licensed C-39 Roofing and General Contractor, in business since 1979.

Eastman Roofing & Waterproofing has served Silicon Valley homeowners with this same repair-first approach since 1979. Homeowners weighing a similar ventilation problem can contact Eastman for an on-site evaluation.